AM-2T-24D PHOTO PII INSULATED BOOM LEAKAGE METERS


MODEL #AM2T24D





PII HAS PRODUCED THE VEHICLE MOUNTED AM-2T INSULATED BOOM LEAKAGE
METERS FOR OVER 10 YEARS, FOR BOTH 12 AND 24 VOLT DC POWERED SYSTEMS.
THEY ARE BUILT IN A 6 X 6 X 4 inch NEMA 12 ENCLOSURE WITH HINGED DOOR.
THEIR PURPOSE IS TO PROVIDE CONTINIOUS METERING OF AC LEAKAGE CURRENT 
ON INSULATED BOOMS AND SOUND AN ALARM, IN THE EVENT THE BOOM LEAKAGE
EXCEEDS A PRESET LEVEL. KEEP A DAILY RECORD OF LEAKAGE, TO CLEARLY
INDICATE TIME FOR MAINTENANCE CLEANING AND TESTING.

MODEL #AM-2T-24D METER..........................................$625.00
      LCD 3.5 DIGIT 0-1,999 AC MICROAMPERES WITH ALARM AT 900 ua,
      IN A 6 X 6 X 4 INCH NEMA 12 ENCLOSURE FOR DIRECT TRUCK MOUNTING
      ON VEHICLES WITH INSULATED BOOMS. POWERED BY VEHICLE BATTERY.

FORMERLY WITH RUGGEDIZED TAUT BAND ANALOG METERS, THEY RECENTLY 
UPGRADED THEM WITH THE FOLLOWING FEATURES:

RUGGED LCD METER FOR: BETTER VIBRATION AND SHOCK RESISTANCE
		      AUTO RANGING UP TO 1,999 ua AC
		      1,000V ISOLATED 9 VOLT DC-DC POWER SOURCE

DUAL DC POWER INPUT:  FOR USE ON 12 OR 24 VOLT VEHICLES, WITH
		      REVERSE POLARITY PROTECTION TO 1,000 VOLTS

ADDITIONAL FEATURES:  BUILT-IN ALARM RESET SWITCH, MULTIPLE VARISTOR
		      AND ZENER CLAMPING OF SIGNAL AND POWER LINES.
		      BNC CONNECTOR FOR LEAKAGE INPUT, WITH 45 FOOT
		      RG58 COAX CABLE INCLUDED. AMPHENOL POWER INPUT
		      CONNECTOR PROVIDED FOR 12/24 VOLT POWER SOURCE.

POWER REQUIREMENTS:   1/10 AMPERE AT ALARM CONDITION

SHIPPING WEIGHT:      8 POUNDS PER UNIT	

UNITS ARE FACTORY PRESET TO ALARM AT 900ua (OR YOUR REQUESTED LEVEL)
OF AC LEAKAGE AND PROVIDE CONTINIOUS MONITORING OF LEAKAGE CURRENT 
FOR BOTH OPERATOR PROTECTION AND EQUIPMENT MAINTENANCE SCHEDULING.

For More info call 941-283-8640 or FAX 941-283-8631 or EMAIL TO PII or SNAIL MAIL TO: PII, 3516 DELILAH DRIVE, CAPE CORAL, FLORIDA 33993